stephane hello,
I said something stupid to you previously. interceptor intercepts at the
wifi level and not as I thought at the 400 or 800 Mhz radio level... sorry!

so normal that you have inTemp and barometer! :-)

I too have a Bresser station and retrieve data automatically from Awekas in
the absence of a USB output. I have several exterior sensors and there is a
somewhat similar problem. the hygrometer values ​​of the probes are
retrieved as hygrometer values ​​of the floor probes while the temperatures
are retrieved as temperatures of external probes.

I reported this anomaly to Bresser in France who already reported it almost
a year ago, knowing that I was not the only one to have reported it to them.
I also reported the problem to Germany who basically told me it was
"normal" operation without explanation....

As I wrote a driver for weewx which retrieves data directly from Awekas at
regular intervals, I reverse the value fields myself...

Le ven. 23 févr. 2024, 23:19, sc.lep...@gmail.com <sc.leprov...@gmail.com>
a écrit :

> Hello
> I use  weewx  with interceptor :
>
> Feb 23 23:09:01 meteo-Ubuntu weewx-BRESSER[63190] DEBUG user.interceptor:
> raw packet: {'dateTime': 1708726142, 'usUnits': 1, 'rain_total': 0.09,
> 'barometer': 29.99, 'temperature_out': 34.7, 'humidity_out': 90.0,
> 'wind_speed': 0.0, 'wind_gust': 0.0, 'wind_dir': 138.0, 'dewpoint': 32.0,
> 'temperature_in': 66.2, 'humidity_in': 57.0, 'uv': 0.0, 'solar_radiation':
> 0.0, 'soil_temperature_1': 66.2, 'soil_temperature_2': 70.8,
> 'soil_moisture_2': 60.0, 'rain': None}
> Feb 23 23:09:01 meteo-Ubuntu weewx-BRESSER[63190] DEBUG user.interceptor:
> mapped packet: {'dateTime': 1708726142, 'usUnits': 1, 'barometer': 29.99,
> 'outHumidity': 90.0, 'inHumidity': 57.0, 'outTemp': 34.7, 'inTemp': 66.2,
> 'windSpeed': 0.0, 'windGust': 0.0, 'windDir': 138.0, 'radiation': 0.0,
> 'dewpoint': 32.0, 'rain': None, 'UV': 0.0, 'soilTemp1': 66.2, 'soilTemp2':
> 70.8, 'soilMoist2': 60.0}
>
> I dont understand how to use :
> soilTemp1': 66.2, '
> soilTemp2': 70.8, '
> soil_moist1': 60.0,
> soil_moist2': 60.0,
>
> I've 2 temperatures probes
>
> Can someone explain me how to add this in weewx.conf ?
>
> in section  :
>  [[sensor_map_extensions]]
> ???        inTemp = temperature_1
>  ???       inHumidity = humidity_1
>  ???       outTemp = temperature_4
>   ???      outHumidity = humidity_4
>
>
> Thanks a lot  ;)
>
> Stephane
>
> --
> You received this message because you are subscribed to the Google Groups
> "weewx-user" group.
> To unsubscribe from this group and stop receiving emails from it, send an
> email to weewx-user+unsubscr...@googlegroups.com.
> To view this discussion on the web visit
> https://groups.google.com/d/msgid/weewx-user/c851119a-b274-4ecd-99a3-605d2e393946n%40googlegroups.com
> <https://groups.google.com/d/msgid/weewx-user/c851119a-b274-4ecd-99a3-605d2e393946n%40googlegroups.com?utm_medium=email&utm_source=footer>
> .
>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to weewx-user+unsubscr...@googlegroups.com.
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/CADhm9Yf4z%3DAm12NEJYBFe6vDQbAUWz-H74mNWnenaQGQ5SdQOg%40mail.gmail.com.

Reply via email to