Thank you Sir,
runsp_lapw -it gave me an error:  foreach. So I am running with runsp_lapw .... 
 script.  

If I run it with Rkmax=6 then it does not show me any warning. At the FAQ of 
Wienk page standard RMT for O is 6.5 but it also gave me RKmax reduced warning.
 
If someone advises me that I can take RKMAX=6 for O2 system then only I can 
proceed.
I do not have any good facility.


   

 On Tuesday, 7 November 2017 6:59 PM, Gavin Abo <[email protected]> wrote:
 

  To make that calculation feasible, it looks like you need a better computing 
system like a small cluster and mpi. If ~8 GB is your total RAM, keep in mind 
that the Linux operating might use around 1 GB.  Using top 
[https://superuser.com/questions/282867/why-does-the-memory-usage-in-top-not-add-up
 ] or a system monitor 
[https://askubuntu.com/questions/29757/what-can-replace-system-monitoring-in-the-top-gnome-panel-in-unity
 ], you can check for any unnecessary processes and kill them to try to gain 
back more "free" memory.  Though, while this might help a little with memory, 
it likely won't help with the speed issue. For speed, you likely need mpi or 
iterative diagonalization.  Are using iterative diagonalization (runsp -it) as 
was mentioned before:
  http://zeus.theochem.tuwien.ac.at/pipermail/wien/2017-November/027303.html If 
none of that helps, it looks like your stuck with doing less accurate 
calculations using small RKmax values.
  On 11/6/2017 9:24 AM, chin Sabsu wrote:
  
  Thank you Sir, 
  
  As per memory test, I got the figure: 46743  it means ~4.5 GB RAM is enough 
to run the case. But my system is having ~8 GB RAM:  
  7.6 GiB
  Intel® Core™ i5-3570K CPU @ 3.40GHz × 4 
  Intel® Ivybridge Desktop 
  
  
  Dear Lyudmila Dobysheva 
  I increase NMATMAX  upto45000 and NUME at 10000. At this value, it gave me 
lapw1 error while at  NMATMAX (NUME)=35000(8000) it taking too much time and 
even after three hrs lapw1 is running.
   
  I want to keep consistent RKMAX with the literature. Otherwise, my job is to 
calculate the thermodynamic stability and for the same, I need the cohessive 
energy of O also. 
  
  
  Can I use RKmax 6.0 for O2 and for others I am tacking 7. If not then what 
should I do to run this O2 system? 
  
  Chin
   
 _______________________________________________
Wien mailing list
[email protected]
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/[email protected]/index.html


   
_______________________________________________
Wien mailing list
[email protected]
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/[email protected]/index.html

Reply via email to