MessageBodyReader.readFrom throws IOException is turned into
WebApplicationException but might just need to propagate out?
--------------------------------------------------------------------------------------------------------------------------
Key: WINK-31
URL: https://issues.apache.org/jira/browse/WINK-31
Project: Wink
Issue Type: Bug
Components: Server
Reporter: Bryant Luk
Priority: Minor
In the event that a MessageBodyReader.readFrom were to throw an IOException, I
believe that the IOException should propagate out "untouched" (i.e. don't turn
it into a WebApplicationException). This allows the error handling chain (or
the underlying container's error handling capabilities) to map it like a
IOException instead of having someone doing a getCause() on the
WebApplicationException.
Around line 135 in wink-server/src/main/java
org.apache.wink.server.internal.registry.ServerInjectableFactory is where the
change would need to start to be made.
I'm open for debate on this one since the spec is vague and unclear on this
behavior.
--