Ethernet port acting up ? As in connecting / disconnecting ? Make sure
you have it set for "long cable", if that doesn't work - disable
auto-negotiation and try 100mbps half duplex, if that don't work -
10mbps full duplex and then last try 10mbps HALF duplex......

JohnnyO


x
-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On
Behalf Of Brian Rohrbacher
Sent: Tuesday, September 12, 2006 7:56 AM
To: WISPA General List
Subject: Re: [WISPA] MT power supplies


It's actually the ethernet port acting up.  Thought maybe it was lack of

power.

Mac Dearman wrote:

> I don't think a RB532 will run 2 SR5's with a 2' patch cable and a 
>48VDC power supply without s0me weirdness happening. I only put one 
>Super Range card in a RB532 and one Atheros or Prism card.
>
>Mac
>
>
>-----Original Message-----
>From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On

>Behalf Of Brian Rohrbacher
>Sent: Monday, September 11, 2006 11:29 PM
>To: Conversations over a new WISP Trade Organization
>Subject: [WISPA] MT power supplies
>
>I have a RB 532 on 300 foot of cat 5 with 2 sr5.
>I'm using poe 48v .700a power supply.
>I'm seeing weirdness.
>
>Do I have enough "juice"
>
>Brian
>  
>
-- 
WISPA Wireless List: wireless@wispa.org