We are still experimenting with aligning sector's on our towers. We are attempting to use 3 120 degree/13db/6.5 vb/7 degree downtilt, antennas to cover 360 degrees. I just inspected the towers myself, and noticed they are setup at 30 degrees/150 degrees/290 degrees (so they aren't right exactly). So the problem that caused me to inspect the tower was the signal level I can see the other AP's at.
AP 30 can see AP 150 at -39 and AP 290 at -42. AP 150 can see AP 30 at -42 and AP 290 at -70. AP 290 can see AP 30 at -39 and AP 150 at -65. So I'm guessing that the reason 150/290 are much higher is because of the additional 20 degrees between them. These AP's are on channels 1/6/11, I'm wondering if I should worry about seeing the other AP's with such a hot signal, and if so what are some good ways to isolate them better. Regards Michael Baird -------------------------------------------------------------------------------- WISPA Wants You! Join today! http://signup.wispa.org/ -------------------------------------------------------------------------------- WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/