You might try this, Bring up Dev. Studio, delete the COM from COM/DCOM object in the studio, then re-add the object into Dev. Studio. Then Open the Taf an make sure there is no issues with the object and save it back out.
Also, There might be 2 Witango services running. Ben Johansen - http://www.pcforge.com Authorized Witango Reseller http://www.pcforge.com/WitangoGoodies.htm Authorized MDaemon Mail Server Reseller http://www.pcforge.com/AltN.htm -----Original Message----- From: Bryan Hughes [mailto:[EMAIL PROTECTED] Sent: Friday, August 15, 2003 11:07 AM To: [EMAIL PROTECTED] Subject: Witango-Talk: Application Termination of CLASS Files Upgraded to Witango Server version 5.01.062 from 5.01.054 and began have class file problems. Noticed that pages calling COM objects or TCF would execute then abruptly quit, returning no error information to the browser. When look at the Witango logs I see the beginning execution of the TAF the when it came to the TCF or COM object I get an error of... [Application File] TERMINATED /tcf/BofA_eStore.tcf or [Create Object Action] Create_GMEngine_Class [Query] (object creation of object COM://GMCOM.GMEngine.1:Method$gmcom [Thread] Returning results [Application File] TERMINATED /tcf/eogm.tcf I would also get an error in Windows Application log of The description for Event ID ( 10 ) in Source ( Witango_Server_5 ) cannot be found. The local computer may not have the necessary registry information or message DLL files to display messages from a remote computer. The following information is part of the event: [1524] System Exception at 005307b0; Thread ID=1468; Code=EXCEPTION_ACCESS_VIOLATION Read: 8d51b8b5;. The description for Event ID ( 10 ) in Source ( Witango_Server_5 ) cannot be found. The local computer may not have the necessary registry information or message DLL files to display messages from a remote computer. The following information is part of the event: [1524] The "/gmtest.taf" application file, action "Create_GMEngine_Class", caused an unrecoverable OS exception. I thought this might have been a problem with the 3rd party COM Object, but the TERMINATION also occurs on TCF I created in Witango. I have since reverted back to 5.01.054 and everything is working fine. Any ideas, I'd like to move to 5.01.062 since it has the vulnerability fixes. ________________________________________________________________________ TO UNSUBSCRIBE: Go to http://www.witango.com/maillist.taf ________________________________________________________________________ TO UNSUBSCRIBE: Go to http://www.witango.com/maillist.taf