On 21/11/2014 20:38, Bill Somerville wrote:
> On 21/11/2014 20:12, Bill Somerville wrote:
>
> Hi again Chris,
>
> more info below ...
>> On 21/11/2014 19:48, Chris Elmquist wrote:
>>
>> Hi Chris,
>>
>>> On Friday (11/21/2014 at 07:14PM +0000), Bill Somerville wrote:
>>>> Hamlib does deal with this issue but only when you select either DTR or
>>>> RTS as the PTT port. Your set up is a little unusual in that you are
>>>> using CAT commands for PTT and also have the DTR line linked to PTT.
> I think I see the problem, there is a defect in hamlib and it is not
> clearing the control line used for PTT when the PTT port is the same
> port as the CAT port.
>
> I will sort out a patch for hamlib and send you a test version shortly.
Here is a build of WSJT-X v1.4.0-rc3 with the patched hamlib code. 
Please try it using "PTT Method" DTR and the PTT serial port set to the 
same port as the CAT port. Let me know how it goes please?

https://dl.dropboxusercontent.com/u/4192709/wsjtx-1.4.0-rc3.x86_64-r4595.rpm

>
> 73
> Bill
> G4WJS.
73
Bill
G4WJS.

------------------------------------------------------------------------------