No...nothing is being received from the rig at all.  Every command times out.  
The TM-D710 driver just doesn't fail but tries to continue on anyways.So, 
either your com port is wrong, the baud rate is wrong, or the rig isn't 
responding as expected.But you said it did work with some other software, right?
de Mike W9MDB



      From: Edfel Rivera <edfelj...@gmail.com>
 To: wsjt-devel@lists.sourceforge.net 
 Sent: Friday, August 5, 2016 7:48 PM
 Subject: [wsjt-devel] Kenwood TM V71 not recognized - WSJTX 1.7 Devel
   
Followed Mike's (W9MDB) advise, running the test again (wsjtx build 7005) using 
TM -D710 model (234) there is some progress as rig seems detected.  It seems to 
wait for command. 

However when trying WSJTX 1.7 Devel Front-End I can not make the program return 
an OK  (green response) the rig still not detected.  Have tried modification of 
settings but no progress.

Any other idea or suggestion will be appreciate  BTW Kenwood TM v71 have a 
large base as a somehow affordable Echolink ready rig.   Finding a fix for this 
should be a very appreciated help!

Thanks and 73'!
  
Edfel
KP4AJ


(JTSDK-QT 5.2 ) C:\JTSDK\wsjtx\devel\qt52\1.7.0\Release\install\bin)rigctl-wsjtx
 -m 234 -r com5 -s 9600 -vvvvv
rigctl, Hamlib 3.1~git
Report bugs to <hamlib-develo...@lists.sourceforge.net>

rig:rig_init called
initrigs3_kenwood called
rig_register (213)
rig_register (201)
rig_register (225)
rig_register (203)
rig_register (204)
rig_register (216)
rig_register (224)
rig_register (205)
rig_register (207)
rig_register (209)
rig_register (210)
rig_register (222)
rig_register (214)
rig_register (230)
rig_register (221)
rig_register (229)
rig_register (238)
rig_register (202)
rig_register (211)
rig_register (206)
rig_register (208)
rig_register (215)
rig_register (226)
rig_register (217)
rig_register (233)
rig_register (220)
rig_register (223)
rig_register (227)
rig_register (234)
rig_register (231)
rig_register (239)
rig_register (237)
rig_register (228)
rig_register (219)
rig_register (232)
rig_register (236)
kenwood_init called
kenwood_init: if_len = 37
rig:rig_open called
tmd710_get_vfo: called
tmd710_get_vfo_char: called
kenwood_transaction called
kenwood_transaction: cmdstr = BC
write_block(): TX 3 bytes
0000    42 43 0d                                            BC.
read_string(): Timed out 1.100063 seconds after 0 chars
kenwood_transaction: cmdstr = BC
write_block(): TX 3 bytes
0000    42 43 0d                                            BC.
read_string(): Timed out 1.101062 seconds after 0 chars
kenwood_transaction: cmdstr = BC
write_block(): TX 3 bytes
0000    42 43 0d                                            BC.
read_string(): Timed out 1.101063 seconds after 0 chars
kenwood_transaction: cmdstr = BC
write_block(): TX 3 bytes
0000    42 43 0d                                            BC.
read_string(): Timed out 1.101063 seconds after 0 chars
Opened rig model 234, 'TM-D710'
Backend version: 0.6b, Status: Beta

Rig command:

------------------------------------------------------------------------------

_______________________________________________