I've noted the following repeatable behavior when switching back and 
forth between MSK144 and the (relatively) new FreqCal mode.  It's 
tripped me up several times, because I almost always use T/R = 15 s for 
MSK and don't always notice right away that the program (WSJT-X, r7599) 
has changed it to 30 s.

running mode MSK144:  T/R time is 15 s

change mode to FreqCal:  T/R time changes to 30 s

change mode back to MSK144:  T/R time remains at 30 s

I suppose this is not unreasonable behavior, as 30 s is an allowable T/R 
time in MSK144, but I would much prefer that the previously set (15 s) 
T/R time be remembered when switching from and back to the mode.

... Rich    W2RG

------------------------------------------------------------------------------