I've noted the following repeatable behavior when switching back and forth between MSK144 and the (relatively) new FreqCal mode. It's tripped me up several times, because I almost always use T/R = 15 s for MSK and don't always notice right away that the program (WSJT-X, r7599) has changed it to 30 s.
running mode MSK144: T/R time is 15 s change mode to FreqCal: T/R time changes to 30 s change mode back to MSK144: T/R time remains at 30 s I suppose this is not unreasonable behavior, as 30 s is an allowable T/R time in MSK144, but I would much prefer that the previously set (15 s) T/R time be remembered when switching from and back to the mode. ... Rich W2RG ------------------------------------------------------------------------------ Announcing the Oxford Dictionaries API! The API offers world-renowned dictionary content that is easy and intuitive to access. Sign up for an account today to start using our lexical data to power your apps and projects. Get started today and enter our developer competition. http://sdm.link/oxford _______________________________________________ wsjt-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/wsjt-devel