On 08/03/2018 15:56, Ted Gisske wrote:
Has anyone had success using a VSPE splitter to direct both N1MM+ and
WSJT-X to the same rig-control port (in my case a TS-990 on COM4). If
so, I’d appreciate knowing how you got it done. The splitter seems to
work OK with N1MM, but WSJT-X refuses to connect.
Thanks!
Ted
K9IMM
Hi Ted,
dumb serial port splitters are not supported by WSJT-X, nor will it be
as there is no way to reconcile conflicts. WSJT-X does support CAT
control sharing by other more reliable mechanisms like the Hamlib
rigctld server, Omni-Rig on Windows, using HRD as a rig control proxy,
using DX Lab Suite Commander as a rig control proxy. If N1MM+ can talk
to any of them you may have more success.
73
Bill
G4WJS.
------------------------------------------------------------------------------