I have found a similar random seeming event but somewhat frequent.  I use the 
Tune button with the power slider to create a variable level signal for my VHF+ 
power meter calibration and amplifier testing so I use it a lot at times.  I 
find I turn tune on while in FT8 at random times for my test, don’t care about 
period, and it turns on but then immediately turns off.  Have not nailed down 
the exact conditions yet as I am not usually looking at the screen, instead 
watching my meters and relays.  Not double clicking.   I happen to have the TX 
1st button checked.  I will uncheck it and watch.

It behaves like a single mouse event gets treated as a double click event.  I 
also see this randomly with the Erase button.  1 click to clear the RX window 
and sometimes both windows clear.  I am sure I did not double click but it is a 
wireless mouse and while other things seem to work as expected, who knows.


Mike
K7MDL  EL87sm & CN88sf

From: Al <k...@arrl.net>
Sent: Tuesday, November 3, 2020 13:01
To: WSJT software development <wsjt-devel@lists.sourceforge.net>
Subject: [wsjt-devel] RC1 Tune problem

You may already have  this one..

1) With TX odd/1st selected and observe the TX audio out of WSJT...
2) at 3 seconds into the odd period, toggle TUNE on then off.
3) TX audio starts when TUNE is toggled on and then off briefly and then back 
on until the end of the period.

AL, K0VM

_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel

Reply via email to