We are trying to boot NextScale nodes with our RedHat 6.4 stateless image.
They are crashing during the initrd boot process with following error:
dracut Warning: No root device "1" found
dracut Warning: Boot has failed. To debug this issue add "rdshell" to the
kernel command line.
dracut Warning: Signal caught!
dracut Warning: Boot has failed. To debug this issue add "rdshell" to the
kernel command line.
Kernel panic - not syncing: Attempted to kill init!
Pid: 1, comm: init Tainted: G --------------- H
2.6.32-358.el6.x86_64 #1
Call Trace:
[<ffffffff8150cfc8>] ? panic+0xa7/0x16f
[<ffffffff81073ae2>] ? do_exit+0x862/0x870
[<ffffffff81182885>] ? fput+0x25/0x30
[<ffffffff81073b48>] ? do_group_exit+0x58/0xd0
[<ffffffff81073bd7>] ? sys_exit_group+0x17/0x20
[<ffffffff8100b072>] ? system_call_fastpath+0x16/0x1b
------------[ cut here ]------------
WARNING: at arch/x86/kernel/smp.c:117
native_smp_send_reschedule+0x5c/0x60() (Tainted: G
--------------- H )
Hardware name: IBM NeXtScale nx360 M5: -[5465AC1]-
Modules linked in: sd_mod crc_t10dif ahci mlx4_core [last unloaded:
scsi_wait_scan]
Pid: 1, comm: init Tainted: G --------------- H
2.6.32-358.el6.x86_64 #1
Call Trace:
<IRQ> [<ffffffff8106e2e7>] ? warn_slowpath_common+0x87/0xc0
[<ffffffff8106e33a>] ? warn_slowpath_null+0x1a/0x20
[<ffffffff8102dd9c>] ? native_smp_send_reschedule+0x5c/0x60
[<ffffffff8105ae28>] ? scheduler_tick+0x208/0x260
[<ffffffff810a7fd0>] ? tick_sched_timer+0x0/0xc0
[<ffffffff810811de>] ? update_process_times+0x6e/0x90
[<ffffffff810a8036>] ? tick_sched_timer+0x66/0xc0
[<ffffffff8109b38e>] ? __run_hrtimer+0x8e/0x1a0
[<ffffffff810a182f>] ? ktime_get_update_offsets+0x4f/0xd0
[<ffffffff8107700f>] ? __do_softirq+0x11f/0x1e0
[<ffffffff8109b6f6>] ? hrtimer_interrupt+0xe6/0x260
[<ffffffff81516d7b>] ? smp_apic_timer_interrupt+0x6b/0x9b
[<ffffffff8100bb93>] ? apic_timer_interrupt+0x13/0x20
<EOI> [<ffffffff8150d06d>] ? panic+0x14c/0x16f
[<ffffffff8150cffa>] ? panic+0xd9/0x16f
[<ffffffff81073ae2>] ? do_exit+0x862/0x870
[<ffffffff81182885>] ? fput+0x25/0x30
[<ffffffff81073b48>] ? do_group_exit+0x58/0xd0
[<ffffffff81073bd7>] ? sys_exit_group+0x17/0x20
[<ffffffff8100b072>] ? system_call_fastpath+0x16/0x1b
Any help would be appreciated.
Thanks,
Damir
------------------------------------------------------------------------------
Monitor 25 network devices or servers for free with OpManager!
OpManager is web-based network management software that monitors
network devices and physical & virtual servers, alerts via email & sms
for fault. Monitor 25 devices for free with no restriction. Download now
http://ad.doubleclick.net/ddm/clk/292181274;119417398;o
_______________________________________________
xCAT-user mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/xcat-user