On 06/22/2017 09:41 AM, Nicolas Roosen wrote:
Hi,
On 06/21/2017 06:55 PM, Jarrod Johnson wrote:
If you nodeset <node> shell
Then boot it, ssh in and run bmcsetup by hand, the output may be
informative as to why the BMC didn't get set up correctly.
Practical. So the bmcsetup while run into the shell did successfully set
the correct IP address.
My guess is that the bmcsetup command is not run during the provisioning?
How can I check that?
We found out that bmcsetup didn't run because our node wasn't affected
to a discovered UUID (since we are adding the nodes manually I guess):
# nodediscoverls
UUID NODE METHOD
MTM SERIAL
00000000-0000-0000-0000-0CC47A70F36E undef undef
Supermicro:NONEA00AD6FA
As soon as we affected the node to the correct UUID, bmcsetup worked:
# nodediscoverdef -u 00000000-0000-0000-0000-0CC47A71F39E -n n040-clu
Defined [00000000-0000-0000-0000-0CC47A71F39E] to node n040-clu.
------------------------------------------------------------------------------