> what about comparing not the whole table, but just 1 or 2 values. > For example, you know, that stress after 100 iteration should be > 100MPa, just compare it. >
The test is only comparing 2 values (peak axial stress, and confining stress at the same strain level). But if something changes, it will need inspection of the whole result in order to understand what happens (unbalanced force, initial stability and stability of confinment, etc), thats why I commited a complete result for reference. The current input/output data can also be used for comparisons with other DEM codes. Bruno _______________________________________________ Mailing list: https://launchpad.net/~yade-dev Post to : yade-dev@lists.launchpad.net Unsubscribe : https://launchpad.net/~yade-dev More help : https://help.launchpad.net/ListHelp