> what about comparing not the whole table, but just 1 or 2 values.
> For example, you know, that stress after 100 iteration should be
> 100MPa, just compare it.
>

The test is only comparing 2 values (peak axial stress, and confining
stress at the same strain level).
But if something changes, it will need inspection of the whole result in
order to understand what happens (unbalanced force, initial stability
and stability of confinment, etc), thats why I commited a complete
result for reference.
The current input/output data can also be used for comparisons with
other DEM codes.