Bruno Chareyre proposed the following answer:
targetDt can be anything, it doesn't matter. You need to think in a "per
iteration" way for e.g. strain rate, and then it doesn't matter what dt is.
Quasi-static means independent of inertial effects, thus independent of
what you do with density (be it for fabric or other things).
I don't know any publication about this other than PFC manual.
--