Question #670501 on Yade changed:
https://answers.launchpad.net/yade/+question/670501

Bruno Chareyre proposed the following answer:
>you can use larger timestep than PWaveTimeStep as the mass of a clump
is higher than that of a single sphere

Note that GlobalStiffness time stepper accounts for that, so it should give 
automaticaly a larger timestep.
B

-- 