i have yet some more to add on to the description here. if i create a new 
performance template under the /Devices/Servers class and name it Device, that 
performance template overrides the one applied at /Devices. Then, everything 
works. So, that partially resolves my problem, but is there no way to have more 
than one performance template applied to a device? If not, it isn't really 
utilizing all of the features of a hierarchical model. I'd like to have a more 
general performance template applied to the /Devices/Servers class and then get 
more specific at each class down the tree while maintaining the monitors 
configured on each level above. Maybe I'm asking too much out of a monitoring 
system :)