On 5/10/07, Barry Stephen (YDD08) Derwent Shared Services
<[EMAIL PROTECTED]> wrote:
Hello everybody
just started running the new vmware image.
the problem I have is a recurring messsage under localhost events that
is coming from Zenwinmodeller
wmi failed 67: Desc
I have no DHCP on the subnet that the vmware server is on so I have
manually set an IP which is working OK in case that is relevant.
I have set zProperties/zWmiMonitorIgnore to True for localhost but I am
getting the info below in the zenwinmodeler log.
Why is Zenoss trying to model this device using WMI, Its linux! Anyone
having this problem? Anyone got any ideas?
This is a common problem with the beta. It has been fixed in the
latest version, but you can fix yours manually.
Set zWmiMonitorIgnore to True on /Devices
Set zWmiMonitorIgnore to False on /Devices/Server/Windows
--
Chet Luther