On 5/10/07, Barry Stephen (YDD08) Derwent Shared Services
<[EMAIL PROTECTED]> wrote:
Hello everybody

just started running the new vmware image.

the problem I have is a recurring messsage under localhost events that
is coming from Zenwinmodeller

wmi failed 67: Desc

I have no DHCP on the subnet that the vmware server is on so I have
manually set an IP which is working OK in case that is relevant.

I have set zProperties/zWmiMonitorIgnore to True for localhost but I am
getting the info below in the zenwinmodeler log.

Why is Zenoss trying to model this device using WMI, Its linux! Anyone
having this problem? Anyone got any ideas?

This is a common problem with the beta. It has been fixed in the
latest version, but you can fix yours manually.

Set zWmiMonitorIgnore to True on /Devices
Set zWmiMonitorIgnore to False on /Devices/Server/Windows

--