I'm confused...(nothing new there)...I am getting values for the same OID for different interfaces.
As an example: ifOutOctets (.1.3.6.1.2.1.2.2.1.16) For .1.3.6.1.2.1.2.2.1.16.1 (as well as .2 and .3) I can poll values. But I'm getting the bad OID msgs when Zenoss tries to poll .1.3.6.1.2.1.2.2.1.16.4. An snmp walk of .1.3.6.1.2.1.2.2.1.16 shows there is no .4 (or .5, .6 etc...but I don't get errors for those). So, I want to be able to graph for the interfaces that work. If I change the template for that entire interface type, it won't collect that info...I don't know how to get it to ignore the missing interfaces. I'm having this problem on all my routers on various interface types (T1, BRI, ATM, ATM subif), etc. Thx! -------------------- m2f -------------------- Read this topic online here: http://community.zenoss.com/forums/viewtopic.php?p=8915#8915 -------------------- m2f -------------------- _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users