The reason you are seeing this is because the wrong templates are being applied to the interfaces. It appears that zeonss is applying csmacd type queries to all interfaces, regardless of their type. That's why we are seeing perf alerts on Nu and Po interfaces, and why you are getting invalid OIDs on your non-Ethernet interfaces.
The bug (#1806) reported hasn't been updated yet, so I would just hang loose. That's what I'm doing, because there has to be a nice easy way to change which templates are assigned by default. Updating each device after it is added only works if you've got a handful of devices. ------------------------ Michael Brown -------------------- m2f -------------------- Read this topic online here: http://community.zenoss.com/forums/viewtopic.php?p=8929#8929 -------------------- m2f -------------------- _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users