If by "register with Zenoss" you mean the little red/green dot on the OS tab I 
have to disappoint you. Zenoss actually doesn't monitor interfaces on a device.
When the change registers with Zenoss it actually is due to our remodeling 
process re-running and then discovering that the interface is no longer 
available.
If you want to keep track of your interfaces you would have to add the OID to a 
template and then raise a threshold alert if the OID comes back with anything 
but 1. You could then even run a script to change the status light on the OS 
tab.




-------------------- m2f --------------------

Read this topic online here:
http://community.zenoss.com/forums/viewtopic.php?p=10277#10277

-------------------- m2f --------------------