This is off the cuff, haven't actually tried any of this:
For CPU load, you could probably use the current threshold system to
trigger an event at above 95%. Set the clear conditions for the event
such that dropping below 95% clears the event. Then I'd create the
alerting rule so that the count is greater than the number that would be
generated in 5 minutes. I think it polls SNMP every 60 seconds, so count
> 5 ought to get what you want.
For checking a certain folder - do the same, but use a command
datasource, and check the cycle time for that. I believe it is also 60
seconds by default, but I could be wrong.
--
James Pulver
Information Technology Area Supervisor
LEPP Computer Group
Cornell University
Jarmila wrote:
I'm new with Zenoss and I'd like to ask few questions about creating event
alerts. I want to create few more complex alerting rules e.g.
- CPU load is above 95% for more than 5 minutes
- check certain folder if there is any file more than 10 minutes (it will be
used for watching hotfolders)
I think they are pretty complex alerting rules and I'd like to ask someone for
little help, how to create those alerting rules.
-------------------- m2f --------------------
Read this topic online here:
http://community.zenoss.com/forums/viewtopic.php?p=23727#23727
-------------------- m2f --------------------
_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users
_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users