Maybe this is my misunderstanding of how Zenoss works, but I've been trying to
get two Cisco Catalyst 2960G's to map the OID for the hardware model to the
actual model name. I've been able to successfully load the MIBs for Cisco, and
this is what I'm getting for the following output:
>From Zenoss GUI, snmpwalk command:
----------------------------------------------
Command: snmpwalk -v1 -c${device/zSnmpCommunity} ${here/manageIp} system
Description:
Output:
==== mgtsw00-393-01 ====
snmpwalk -v1 -cpublic 10.10.151.6 system
SNMPv2-MIB::sysDescr.0 = STRING: Cisco IOS Software, C2960 Software
(C2960-LANBASE-M), Version 12.2(35)SE5, RELEASE SOFTWARE (fc1)
Copyright (c) 1986-2007 by Cisco Systems, Inc.
Compiled Thu 19-Jul-07 20:06 by nachen
SNMPv2-MIB::sysObjectID.0 = OID: SNMPv2-SMI::enterprises.9.1.696
<------doesn't resolve this MIB completely
DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (796306903) 92 days, 3:57:49.03
SNMPv2-MIB::sysContact.0 = STRING:
SNMPv2-MIB::sysName.0 = STRING: mgtsw00-393-01
SNMPv2-MIB::sysLocation.0 = STRING:
SNMPv2-MIB::sysServices.0 = INTEGER: 2
SNMPv2-MIB::sysORLastChange.0 = Timeticks: (0) 0:00:00.00
DONE in 0 seconds on 1 targets
----------------------------------------------
Output from snmptranslate:
----------------------------------------------
[EMAIL PROTECTED] mibs]$ snmptranslate .1.3.6.1.4.1.9.1.696
SNMPv2-SMI::enterprises.9.1.696
[EMAIL PROTECTED] mibs]$ snmptranslate -m
/usr/local/zenoss/zenoss/share/mibs/ietf/SNMPv2-SMI:/usr/local/zenoss/zenoss/share/mibs/site/CISCO/CISCO-SMI.mib:/usr/local/zenoss/zenoss/share/mibs/site/CISCO/CISCO-PRODUCTS-MIB.mib
.1.3.6.1.4.1.9.1.696
CISCO-PRODUCTS-MIB::catalyst2960G24
[EMAIL PROTECTED] mibs]$
----------------------------------------------
My question is, is there something I'm missing (like exporting the SMIPATH)
that will make snmptranslate work correctly, or does Zenoss resolve OID's from
a different method/interface? If the later, what do I need to change to get
the modeler to resolve this OID correctly?
Haven't been able to find a solution in the other posts in the last several
days of searching.
-------------------- m2f --------------------
Read this topic online here:
http://community.zenoss.com/forums/viewtopic.php?p=23788#23788
-------------------- m2f --------------------
_______________________________________________
zenoss-users mailing list
[email protected]