2008/10/14 jholz7 <[EMAIL PROTECTED]>

> I've been testing out Zenoss for use on our company's Intranet, and for the
> most part I've been very pleased.  I have run into one problem that I can't
> figure out though.
>
> When I set up the machine, it was only a test machine, so we named it
> snmpTest.hostname.  Well, now we are moving it to be the main snmp checker,
> so we changed the hostname from snmpTest to just snmp.  I made the change in
> linux, and also changed it on our dns servers.
>
> Well, now I get these errors every minute:
>
>        snmpTest |zenwin|/Status/Heartbeat||4|snmpTest  zenwin heartbeat
> failure
>
> I get one for each zen* process (zenwin, zentrap, zensyslog, zenstatus,
> etc.)
>
> How can I change it so that it looks for these on snmp. instead of
> snmpTest.?  I've already changed the name of the device, or at least
> snmpTest doesn't show up in devices at all.  How can I make these errors go
> away?  Thanks for your help!
>
>
>
Select "Event Manager" from the LHS menu, then under the drop down triangle
select "Clear All Heartbeats...".

-- 
Regards,