I have a 64 bit windows 2003 sp1 machine running on 2x dual core AMD Operon 
processors.  Everything is working all collectors are collecting, except i 
can't get  wmi to work.  The errors are as follows.

===============
When I add the device
===============
2009-01-07 12:36:25 INFO zen.Utils Executing command: 
/usr/local/zenoss/zenoss/bin/zenmodeler run --now -F -d HTLVDCVAS --weblog 
2009-01-07 12:36:26 INFO zen.ZenModeler Connected to ZenHub 
2009-01-07 12:36:26 INFO zen.ZenModeler Collecting for device HTLVDCVAS 
2009-01-07 12:36:26 INFO zen.ZenModeler WMI collector method for device 
HTLVDCVAS 
2009-01-07 12:36:26 INFO zen.ZenModeler plugins: zenoss.wmi.WinServiceMap 
2009-01-07 12:36:26 INFO zen.ZenModeler No Python plugins found for HTLVDCVAS 
2009-01-07 12:36:26 INFO zen.ZenModeler No command plugins found for HTLVDCVAS 
2009-01-07 12:36:26 INFO zen.ZenModeler SNMP collection device HTLVDCVAS 
2009-01-07 12:36:26 INFO zen.ZenModeler plugins: zenoss.snmp.NewDeviceMap, 
zenoss.snmp.DeviceMap, zenoss.snmp.InterfaceMap, zenoss.snmp.RouteMap, 
zenoss.snmp.IpServiceMap, zenoss.snmp.HRFileSystemMap, 
zenoss.snmp.HRSWInstalledMap, zenoss.snmp.HRSWRunMap, 
zenoss.snmp.InformantHardDiskMap, zenoss.snmp.HPCPUMap 
2009-01-07 12:36:26 INFO zen.ZenModeler Portscan collector method for device 
HTLVDCVAS 
2009-01-07 12:36:26 INFO zen.ZenModeler plugins: zenoss.portscan.IpServiceMap 
2009-01-07 12:36:26 INFO zen.ZenModeler Running 3 clients 

===============
ERROR SECTION BEGIN
===============

2009-01-07 12:36:27 ERROR p.w.Query NT_STATUS_ACCESS_DENIED 
Traceback (most recent call last): File 
"/usr/local/zenoss/python/lib/pysamba/wbem/Query.py", line 167, in inner yield 
deferred(ctx); driver.next() File 
"/usr/local/zenoss/zenoss/Products/ZenUtils/Driver.py", line 64, in result 
raise ex WMIFailure: NT_STATUS_ACCESS_DENIED 

==============
ERROR SECTION END
==============

2009-01-07 12:36:27 INFO zen.ZenModeler No change in configuration detected 
2009-01-07 12:36:29 INFO zen.PortscanClient portscan client finished collection 
for HTLVDCVAS 
2009-01-07 12:36:29 INFO zen.ZenModeler processing Ip Services for device 
HTLVDCVAS 
2009-01-07 12:36:30 INFO zen.ZenModeler Changes in configuration applied 
2009-01-07 12:36:31 INFO zen.SnmpClient snmp client finished collection for 
HTLVDCVAS 
2009-01-07 12:36:31 INFO zen.ZenModeler processing zenoss.snmp.NewDeviceMap for 
device HTLVDCVAS 
2009-01-07 12:36:31 INFO zen.ZenModeler processing zenoss.snmp.DeviceMap for 
device HTLVDCVAS 
2009-01-07 12:36:31 INFO zen.ZenModeler processing zenoss.snmp.InterfaceMap for 
device HTLVDCVAS 
2009-01-07 12:36:31 INFO zen.ZenModeler processing zenoss.snmp.RouteMap for 
device HTLVDCVAS 
2009-01-07 12:36:31 INFO zen.ZenModeler processing zenoss.snmp.IpServiceMap for 
device HTLVDCVAS 
2009-01-07 12:36:31 INFO zen.ZenModeler processing zenoss.snmp.HRFileSystemMap 
for device HTLVDCVAS 
2009-01-07 12:36:31 INFO zen.ZenModeler processing zenoss.snmp.HRSWInstalledMap 
for device HTLVDCVAS 
2009-01-07 12:36:31 INFO zen.ZenModeler processing zenoss.snmp.HRSWRunMap for 
device HTLVDCVAS 
2009-01-07 12:36:31 INFO zen.ZenModeler processing 
zenoss.snmp.InformantHardDiskMap for device HTLVDCVAS 
2009-01-07 12:36:31 INFO zen.ZenModeler processing zenoss.snmp.HPCPUMap for 
device HTLVDCVAS 
2009-01-07 12:36:31 INFO zen.ZenModeler Changes in configuration applied 
2009-01-07 12:36:31 INFO zen.ZenModeler Scan time: 5.28 seconds 
2009-01-07 12:36:32 INFO zen.ZenModeler Daemon ZenModeler shutting down 
2009-01-07 12:36:32 INFO zen.ZenModeler zenmodeler shutting down 
2009-01-07 12:36:33 INFO zen.PerformanceConf configuration collected 


Unforntunately the error and lines mean nothing to me???


==================
Events after device is added
==================
HTLVDCVAS|zenwin|/Status/Wmi||4|Could not read the status of Windows services 
(NT_STATUS_ACCESS_DENIED). Check your username/password settings and verify 
network connectivity.

HTLVDCVAS|zeneventlog|/Status/Wmi||4|Could not read the Windows event log 
(NT_STATUS_ACCESS_DENIED). Check your username/password settings and verify 
network connectivity

I can confirm the username and password combination is correct as they work for 
all the 32 bit windows boxes, I can log onto the box using it and it is part of 
domain admin.  if I type the following

wmic -U domain/user%password //HTLVDCVAS "select * from Win32_ComputerSystem" 

I get the following error
ERROR: Login to remote object.
NTSTATUS: NT_STATUS_ACCESS_DENIED - Access denied

but if i do this to a 32bit windows box it works.




-------------------- m2f --------------------

Read this topic online here:
http://forums.zenoss.com/viewtopic.php?p=29731#29731

-------------------- m2f --------------------



_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users

Reply via email to