I'd like to append a very important caveat to this discussion: most of the talk 
on Rfree as protection against overfitting is perfectly correct, if your 
dataset is high enough resolution. Remember that Rfree only provides protection 
against one form of overfitting: that is, fitting of atoms into random noise. 
What it doesn't protect well against is fitting the wrong atoms into real 
density. Remember, all your x-ray data ultimately says is "there are electrons 
here" - your R-factors don't care where those electrons come from, as long as 
they're present in about the right numbers (with some fudge-room for B-factors 
and occupancies). If you browse through the back catalogue of >3A models, 
you'll find some with horrendous geometry statistics but remarkably good 
R-factors (both work and free) - ultimately, I think, because the model atoms 
have been "overstuffed" into density that is real according to both the working 
and free data. In quite a few such cases I find that even after extensive 
reworking I'm unable to beat the original R-free, despite every other metric 
improving markedly.

Best regards,

Tristan
________________________________
From: CCP4 bulletin board <CCP4BB@JISCMAIL.AC.UK> on behalf of Barone, Matthias 
<bar...@fmp-berlin.de>
Sent: 20 October 2020 12:59
To: CCP4BB@JISCMAIL.AC.UK <CCP4BB@JISCMAIL.AC.UK>
Subject: Re: [ccp4bb] AW: [ccp4bb] over-fitting? over-refinement?


Eleanor rises a very important practical point here..."sidechains at the 
solvent interface have multiple conformations, and that as a result the water 
networks should also have partial occupancies". I was fighting with such a 
model for half a year and also tested XSHEL (there was a thread in here for 
that..). Coupling partial occupancies of sidchains with waters and other 
sidchains is a horrendously time-consuming task...and in the end, as Eleanor 
said, "correcting these details does not change the Rfactors at all". You just 
get fed up with that puzzle and stop right there.

best, matthias


Dr. Matthias Barone

AG Kuehne, Rational Drug Design

Leibniz-Forschungsinstitut für Molekulare Pharmakologie (FMP)
Robert-Rössle-Strasse 10
13125 Berlin

Germany
Phone: +49 (0)30 94793-284

________________________________
From: CCP4 bulletin board <CCP4BB@JISCMAIL.AC.UK> on behalf of Eleanor Dodson 
<0000176a9d5ebad7-dmarc-requ...@jiscmail.ac.uk>
Sent: Tuesday, October 20, 2020 12:40:19 PM
To: CCP4BB@JISCMAIL.AC.UK
Subject: Re: [ccp4bb] AW: [ccp4bb] over-fitting? over-refinement?

It is always hard to know when to stop tweaking a model.. We know from high 
resolution studies that many sidechains at the solvent interface have multiple 
conformations, and that as a result the water networks should also have partial 
occupancies. But usually correcting these details does not change the Rfactors 
at all - nor contribute much to the biological relevance of your structure!
So often the point to stop is when you get fed up, Phil Evans said years ago - 
I spend 95% of my time on 5% of the structure, most of which is unimportant..
In practice I let the difference maps decide when to stop - 10 Sigma peak - 
think why - lots of 5 Sigma positive and negative ones not so important
Eleanor

On Tue, 20 Oct 2020 at 11:27, Schreuder, Herman /DE 
<herman.schreu...@sanofi.com<mailto:herman.schreu...@sanofi.com>> wrote:

A practice that was very popular before the Rfree came around was to fit a 
water molecule in every noise peak. One would get spectacular low Rfactors this 
way, but I cannot imagine that anyone would believe that this would be fitting 
and not over-fitting.



Best,

Herman



Von: CCP4 bulletin board <CCP4BB@JISCMAIL.AC.UK<mailto:CCP4BB@JISCMAIL.AC.UK>> 
Im Auftrag von Sam Tang
Gesendet: Dienstag, 20. Oktober 2020 05:27
An: CCP4BB@JISCMAIL.AC.UK<mailto:CCP4BB@JISCMAIL.AC.UK>
Betreff: [ccp4bb] over-fitting? over-refinement?



Hi, the question may be a bit weird, but how do you define 'over-fitting' in 
the context of structure refinement? From users' perspective the practical 
aspect is to 'fit' the model into the density. So there comes this question 
from our juniors: fit is fit, how is a model over-fit?



BRS



Sam



________________________________

To unsubscribe from the CCP4BB list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1<https://eur01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fwww.jiscmail.ac.uk%2Fcgi-bin%2FWA-JISC.exe%3FSUBED1%3DCCP4BB%26A%3D1&data=04%7C01%7CHerman.Schreuder%40SANOFI.COM%7Cfca18f01417745b3655008d874a81d74%7Caca3c8d6aa714e1aa10e03572fc58c0b%7C0%7C0%7C637387612965782189%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&sdata=s1FpY1ufI7De3N6J2%2FivUy4zehp%2BcGl1gGjHeNrzUeA%3D&reserved=0>

________________________________

To unsubscribe from the CCP4BB list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1

________________________________

To unsubscribe from the CCP4BB list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1

________________________________

To unsubscribe from the CCP4BB list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1

########################################################################

To unsubscribe from the CCP4BB list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1

This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing list 
hosted by www.jiscmail.ac.uk, terms & conditions are available at 
https://www.jiscmail.ac.uk/policyandsecurity/

Reply via email to