On Thu, Oct 02, 2014 at 08:24:21PM -0400, Ethan Rosenberg wrote: > On 10/01/2014 03:20 PM, Dan Ritter wrote: > >On Sat, Sep 27, 2014 at 11:26:48PM -0400, Ethan Rosenberg, PhD wrote: > >>root@meow:/home/ethan# setserial -g /dev/ttyS[0123] > >>/dev/ttyS0, UART: 16550A, Port: 0x03f8, IRQ: 4 > >>/dev/ttyS1, UART: 16550A, Port: 0x1c90, IRQ: 17 > >> > >>More info from the manual -- > >> > >>9600 baud, 7 data bits, even parity, 1 stop bit > >> > >>Transmits weight and scale status whenever ASCII 'W'<CR> is sent by the POS > >>terminal. > > Minicom set up as 9600,7,e,1. > Terminal ANSI > No response from tapping W.
Check that this is ttyS0, not ttyS1; check that the cable is good; check that the scale is on. Does it need an initialization sequence? -dsr- -- To UNSUBSCRIBE, email to debian-user-requ...@lists.debian.org with a subject of "unsubscribe". Trouble? Contact listmas...@lists.debian.org Archive: https://lists.debian.org/20141003193722.gm5...@randomstring.org