onsdag 26. februar 2003, 15:19, skrev Angel Fradejas:
> Try
>
> regular text: &coding=2
> flash       : &coding=2&mclass=1
>
> and don't forget to use
>
> alt-dcs = yes
>
> on your smsc-group.
>
> If you leave coding unset, you'll have 7bit, and you won't get a dcs that
> is accepted by Vodaphone Spain.

Thanks, but I still can not receive the messages. Do I need to set anything 
else in the smsc-group - ton, npi etc. ?

I am using the same config as the patched 1.1.5, but I receive no messages - 
nether text or binary.

-- 
Med vennlig hilsen,
Eurobate ASA

Arne K. Haaje
Senior Network Engineer
--------------------------------------------------------------------
    Eurobate ASA - Postboks 4589 Nydalen - 0404 Oslo - Norway
Phone: +47 23 22 73 73 - Fax: +47 23 22 73 74 - Mob: +47 92 88 44 66
                    http://www.eurobate.com/