On Sat, Feb 21, 2009 at 07:33:54AM EST, Kalle Olavi Niemitalo wrote: > Chris Jones <cjns1...@gmail.com> writes: > > > Just curious, but what's the relation between the LED's and forms? > > Bug 973, "LED indicators wake system up every 100ms". I guess > that when ELinks was refreshing the display because of the LEDs, > it also redrew the selected link or form control to its internal > display buffer, although it then didn't send the data to the > terminal because the text and attributes matched what already was > there. In ELinks 0.11.1, draw_forms() can read a value from the > form history and set it as the default value of the form control, > and I think that was happening ten times per second. In > 0.12pre1, draw_forms() no longer accesses the form history.
Makes sense. In any event thanks to all .. my system runs about five degrees Celsius cooler now. _______________________________________________ elinks-users mailing list elinks-users@linuxfromscratch.org http://linuxfromscratch.org/mailman/listinfo/elinks-users