Martin Spott wrote:
>Why is setting to 0.0 not sufficient to reach the desired goal ?
>
> Martin.
>
>
This lines only initialize the internal values of the electrical system.
The properties are set in the propagate function :
// publish values to specified properties
for ( i = 0; i < node->get_num_props(); ++i ) {
fgSetFloat( node->get_prop(i).c_str(), node->get_volts() );
}
But this is only done if :
// if this node has found a stronger power source, update the
// value and propagate to all children
if ( volts > node->get_volts() ) {
node->set_volts( volts );
So with the power switches off we have volts == 0 and we never enter the
if statement and the properies stay with their old content.
Harald.
-------------------------------------------------------------------------