It is not a bug. When groups have unique energy axes they should be saved in 
different files. 

Anatoly

> On Oct 8, 2021, at 6:19 PM, Soyoung Kim <soy...@lbl.gov> wrote:
> 
> 
> Dear Bruce and IFEFFIT community,
> 
> Hope all is well. I found a bug with Athena's file export function. I had two 
> normalized mu(E) data with very similar spectra but different x-axis values 
> (collected with different energy step settings).
> <image.png>
> 
> When I batch exported them to a .dat file using the purple E button while 
> "Save next plot to a file" was turned on, the resulting data only had a 
> single x-axis column, which was taken from the first data. Hence, when I plot 
> the two spectra from this .dat file, they now look different:
> <image.png>
> 
> If I export each data individually to .dat files, then they are correct.
> <image.png>
> 
> 
> I'm attaching the Athena project file containing the two data and the .dat 
> files I exported, both together and individually.
> 
> Please let me know if anything is unclear. Thank you in advance for your help.
> 
> Best,
> Soyoung Kim
> 
> <Bug report.prj>
> <exported individual (data2).dat>
> <exported individual (data1).dat>
> <exported together.dat>
> _______________________________________________
> Ifeffit mailing list
> Ifeffit@millenia.cars.aps.anl.gov
> http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
> Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit

_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit

Reply via email to