Allwinner H3 features a thermal sensor like the one in A33, but has its
register re-arranged, the clock divider moved to CCU (originally the
clock divider is in ADC) and added a pair of bus clock and reset.

Update the binding document to cover H3.

Signed-off-by: Icenowy Zheng <icen...@aosc.io>
---
Changes in v3:
- Clock name changes.
- Example node name changes.
- Add interupts (not yet used by the driver).

 .../devicetree/bindings/mfd/sun4i-gpadc.txt        | 25 ++++++++++++++++++++--
 1 file changed, 23 insertions(+), 2 deletions(-)

diff --git a/Documentation/devicetree/bindings/mfd/sun4i-gpadc.txt 
b/Documentation/devicetree/bindings/mfd/sun4i-gpadc.txt
index badff3611a98..986265c59b2a 100644
--- a/Documentation/devicetree/bindings/mfd/sun4i-gpadc.txt
+++ b/Documentation/devicetree/bindings/mfd/sun4i-gpadc.txt
@@ -4,12 +4,21 @@ The Allwinner SoCs all have an ADC that can also act as a 
thermal sensor
 and sometimes as a touchscreen controller.
 
 Required properties:
-  - compatible: "allwinner,sun8i-a33-ths",
+  - compatible: must contain one of the following compatibles:
+               - "allwinner,sun8i-a33-ths"
+               - "allwinner,sun8i-h3-ths"
   - reg: mmio address range of the chip,
   - #thermal-sensor-cells: shall be 0,
   - #io-channel-cells: shall be 0,
 
-Example:
+Required properties for the following compatibles:
+               - "allwinner,sun8i-h3-ths"
+  - clocks: the bus clock and the input clock of the ADC,
+  - clock-names: should be "bus" and "mod",
+  - resets: the bus reset of the ADC,
+  - interrupts: the sampling interrupt of the ADC,
+
+Example for A33:
        ths: ths@01c25000 {
                compatible = "allwinner,sun8i-a33-ths";
                reg = <0x01c25000 0x100>;
@@ -17,6 +26,18 @@ Example:
                #io-channel-cells = <0>;
        };
 
+Example for H3:
+       ths: thermal-sensor@1c25000 {
+               compatible = "allwinner,sun8i-h3-ths";
+               reg = <0x01c25000 0x400>;
+               clocks = <&ccu CLK_BUS_THS>, <&ccu CLK_THS>;
+               clock-names = "bus", "mod";
+               resets = <&ccu RST_BUS_THS>;
+               interrupts = <GIC_SPI 31 IRQ_TYPE_LEVEL_HIGH>;
+               #thermal-sensor-cells = <0>;
+               #io-channel-cells = <0>;
+       };
+
 sun4i, sun5i and sun6i SoCs are also supported via the older binding:
 