On Friday, April 12, 2024 11:31 AM Amit Kapila <amit.kapil...@gmail.com> wrote: > > On Thu, Apr 11, 2024 at 5:04 PM Zhijie Hou (Fujitsu) <houzj.f...@fujitsu.com> > wrote: > > > > On Thursday, April 11, 2024 12:11 PM Amit Kapila <amit.kapil...@gmail.com> > wrote: > > > > > > > > 2. > > > - if (remote_slot->restart_lsn < slot->data.restart_lsn) > > > + if (remote_slot->confirmed_lsn < slot->data.confirmed_flush) > > > elog(ERROR, > > > "cannot synchronize local slot \"%s\" LSN(%X/%X)" > > > > > > Can we be more specific in this message? How about splitting it into > > > error_message as "cannot synchronize local slot \"%s\"" and then > > > errdetail as "Local slot's start streaming location LSN(%X/%X) is > > > ahead of remote slot's LSN(%X/%X)"? > > > > Your version looks better. Since the above two messages all have > > errdetail, I used the style of ereport(ERROR, errmsg_internal(), > > errdetail_internal()... in the patch which is equal to the elog(ERROR but > > has an > additional detail message. > > > > makes sense. > > > Here is V5 patch set. > > > > I think we should move the check to not advance slot when one of > remote_slot's restart_lsn or catalog_xmin is lesser than the local slot inside > update_local_synced_slot() as we want to prevent updating slot in those cases > even during slot synchronization.
Agreed. Here is the V6 patch which addressed this. I have merged the two patches into one. Best Regards, Hou zj