I'd consider a Z-matcher. Telewave, Sinclair, EMR and others make them. You 
don't want to make your transmitter unhappy. You didn't say how bad the SWR is. 
You might get away with doing nothing.

Chuck
WB2EDV



  ----- Original Message ----- 
  From: David Jordan 
  To: Repeater-Builder@yahoogroups.com 
  Sent: Monday, March 22, 2010 10:13 AM
  Subject: [Repeater-Builder] Commercial Antenna for 2m Repeater Question





  Hi Folks,

   

  Our club has been given permission to use one of the Public Safety antennas 
for our 2m repeater. The antenna is a PD-220-3A 150.5-158.5MHz. Our repeater 
freq. is 146.745. The antenna is fed with some nice looking Cell Flex LCF-12-50 
ju, hard-line. The PD-200 is one of those totally enclosed fiberglass antennas; 
we don't have funds to pay for a climb to take down or replace or tweak.  

   

  Have two questions:

   

  We think we can live with the power loss if we build a coupler to match the 
inevitable high SWR.  Can someone point us to a formula to estimate/calculate 
both the projected SWR and power loss, etc? WAGs R fine too.

   

  Is anyone aware of any 2m coupler projects that might work for this scenario? 
Our current repeater antenna is in the attic of one of our members garage at 
25ft ASL.this antenna would be 425ft ASL.so even with losses we expect 
significantly better performance.

   

  73,

  Dave

  WA3GIN 




  


------------------------------------------------------------------------------