Jorge . my K3 displayed the same fault sometime ago .Turned out to
be D1 on the LPA a very fine hairline crack in the solder joint
...without Keith Trinity W6ER's advice in a previous reply to somebody
else , I would never have found it .
It was only visible under a bright
To Dave and Mike I must hold my hands up and admit to starting a "
wild goose chase " .
I had misinterpreted the manual and convinced myself that the power
reduction when pressing TUNE relied on an ATU being installed ... I had
even proved it to myself ... if I did a TUNE at 25W , it
I've just recently bought a used K2 /100 for use at field days with my
local club ( to save my own K2 from getting hammered too much ! ) . I'd
like to use it with a remote ATU . The output of the K2/100 is reduced
to 20 W with an Elecraft ATU installed and the TUNE button pressed
is it
Hello all ,
I've just managed to fix my new to me K2 ... I had always
thought it was less sensitive than it should be , and a check with an XG3
confirmed it .
The Symptoms .
Low sensitivity
Unable to get satisfactory S meter readings despite checking AGC volts and S Hi
and S
If anyone is thinking of selling a KPA100 to raise some money for a KX3 , I'm
interested .
Either the QRO lid version , separate EC2 enclosure version or an unbuilt /
unfinished kit would be fine ...working or not !
73 Steve G1MPW
Just on the off chance I'd like a KPA 100 to go with my newly acquired K2 .
If anyone has one that they would like to sell , either a kit or a
completed one , I'd be very interested .
Many thanks
73 steve G1MPW
6 matches