One of the first tests I did after the dual-fuel conversion of my Honda gen
was with the KPA-500. Worked flawlessly, and I highly recommend the
conversion. It only takes minutes:
https://ae5x.blogspot.com/2020/06/propane-conversion-of-honda-eu2000i.html
73,
John AE5X
Yes, BUT For the 2KW Honda, how long do you want it to run???
SEE "long Run Kits"
https://www.amazon.com/Bergs-System-HND1-2000IS-Single-Tank/dp/B07K385YGX/ref=sr_1_2?dchild=1=honda+generator+extended+run+kit=1618178399=8-2
You can also find the parts to make the kit and modify a "cheap"
I have the big Yamaha inverter generator, an EF6300i. it makes fantastic
electricity and runs any electronic devices with no problems. I do turn
off economy mode if I am only running radio gear. The inverters are much
better than open frame 3600 rpm " box store" units. They have a much
better
I asked the same question on eHam yesterday.
Currently I have a Yamaha EF2800i (lightweight “frame” inverter generator,
29Kg dry), it will power a transceiver and a KPA500 easily, although if
using CW at 400W o/p it runs smoother if economy mode is turned off. It is
fine on eco mode with SSB.
Thanks for sharing!! I have been thinking about adding that to my 2000i.
73, and thanks,
Dave (NK7Z)
https://www.nk7z.net
ARRL Volunteer Examiner
ARRL Technical Specialist, RFI
ARRL Asst. Director, NW Division, Technical Resources
On 4/10/21 6:23 PM, Jim Brown wrote:
On 4/10/2021 5:55 PM,
On 4/10/2021 5:55 PM, Dave Cole wrote:
Was that the Hutch Mountain conversion Jim?
Yes. And Glen said they were great to deal with, including answering
questions. Thanks for prodding my aging memory cells.
73, Jim
__
Elecraft
Was that the Hutch Mountain conversion Jim?
73, and thanks,
Dave (NK7Z)
https://www.nk7z.net
ARRL Volunteer Examiner
ARRL Technical Specialist, RFI
ARRL Asst. Director, NW Division, Technical Resources
On 4/10/21 4:43 PM, Jim Brown wrote:
On 4/10/2021 3:01 PM, Gary Memory wrote:
Anybody know,
On 4/10/2021 3:01 PM, Gary Memory wrote:
Anybody know, or have experience using an Elecraft PA (a 500 watt in my
case) with a generator supplying AC power (a Honda 2 KW in my case)?
We've done that a LOT (at least 6 years) with two KPA500s on Honday
2000i generators for CQP and 7QP
Anybody know, or have experience using an Elecraft PA (a 500 watt in my
case) with a generator supplying AC power (a Honda 2 KW in my case)? I’ve
not done it yet. Wanted to check to see if anyone else has prior experience
before I end up blowing the final, or some such. The Honda flavor I have
9 matches
Mail list logo