[Elecraft] P3 No Longer Matching K3 Signal Level

2014-04-01 Thread Bud Governale
My P3 always matched S meter signal level to the K3. This morning with the S0 on the K3 ( with antenna disconnected) the P3 is displaying a level about 7 db below the S0 level. With antenna connected the K3 shows S7 while the P3 level on the screen is slightly below S0. What happened and how

Re: [Elecraft] P3 No Longer Matching K3 Signal Level

2014-04-01 Thread Alan Bloom
There's an explanation of the reasons for this in the P3 Owner's Manual in the How to set up and Interpret the P3 Display section. Start reading where it says, You would expect the S meter on the K3 and the signal on the P3 display to indicate the same level... Alan N1AL On 04/01/2014

Re: [Elecraft] P3 No Longer Matching K3 Signal Level

2014-04-01 Thread Phil Wheeler
How are Pre and ATT set? As I recall mine matches only with ATT on and Pre off, but I've not looked lately. Phil W7OX On 4/1/14, 11:54 AM, Bud Governale wrote: My P3 always matched S meter signal level to the K3. This morning with the S0 on the K3 ( with antenna disconnected) the P3 is

Re: [Elecraft] P3 No Longer Matching K3 Signal Level

2014-04-01 Thread Alan Bloom
The P3 reads the K3 preamp and attenuator settings and adjusts its gain accordingly for accurate amplitude display. The K3 can be set to either take ATT/PRE into account to keep the S meter reading the same, or not, depending on the SMTR MD menu setting. If set to NOR, that can be one reason