05.10.2021 09:44, Nils Bödeker пишет:
Are there any plans when the next subrelease are published.
Yes, during the next couple of months.
Dmitry
Firebird-Devel mailing list, web interface at
https://lists.sourceforge.net/lists/listinfo/firebird-devel
Hello
with build 4.0.1.2622 the error
Replicaton - INET/inet_error: read errno during replicaton
doesn't happen any more.
Are there any plans when the next subrelease are published.
With best regards
Nils Bödeker
Firebird-Devel mailing list, web interface at
Nils Bödeker wrote 04.10.2021 13:30:
Possible Cause
-
I inserting an Record in the table BINARYDATA an BEFORE_INSERT Trigger Insert
an additional Record in the table OBJECTS. If i disable this Trigger the Error
don't happen.
DML triggers don't fire during replication.
Hello,
I test syncron replication on my testsystem and in one case it appears an error
during the replication process to the slaves.
INET/inet_error: read errno = 10054, server host = firebird-4, address =
192.168.178.74/3050
FIREBIRD-4 Mon Oct 4 10:13:19 2021
REMOTE