Re: [HCP-Users] 7 tesla MRI

2015-02-24 Thread An Vu
Hi Marta, Matt has the right idea here. To get the 1.6-2mm at 7T, I would recommend using IPAT 2, partial fourier 6/8, TE ~20ms. Use the smallest MB factor that will give you TR = 1 second (should be MB = 5). Joseph On Feb 23, 2015, at 10:01 AM, hcp-users-requ...@humanconnectome.org wrote:

Re: [HCP-Users] 7 tesla MRI

2015-02-24 Thread Marta Moreno
Hi Joseph, Thanks for your recommendation! All the best, ___ Marta Moreno-Ortega, Ph.D. Postdoctoral Research Fellow Division of Experimental Therapeutics New York State Psychiatric Institute Department of Psychiatry Columbia University College of Physicians and Surgeons On Feb

[HCP-Users] Questions about the extensively processed rfMRI data

2015-02-24 Thread Aaron C
Dear HCP users, I have some questions about the extensively processed rfMRI data of “parcellation-timeseries-netmats”. Their filenames are “groupICA_3T_Q1-Q6related468_MSMsulc.tar.gz”, “NodeTimeseries_3T_Q1-Q6related468_MSMsulc_ICAd*_ts*.tar.gz”, and

Re: [HCP-Users] Questions about the extensively processed rfMRI data

2015-02-24 Thread Stephen Smith
Hi On 25 Feb 2015, at 03:39, Aaron C aaroncr...@outlook.com wrote: Dear HCP users, I have some questions about the extensively processed rfMRI data of “parcellation-timeseries-netmats”. Their filenames are “groupICA_3T_Q1-Q6related468_MSMsulc.tar.gz”,