Sorry, the latest SLES8 has the latest stuff. I'm not sure about SLES7
stuff. Can you check the source for the 20030221 kernel? (The stuff is in
/drivers/s390/.../hwc.c) It appears you have the support contact with SuSE
so what do they say?
-Original Message-
forgive me if I keep
Okay I've got the TCP/IP rexec daemon running on z/VM. Now I'm
assuming I also have to have a rexec daemon running on my Linux guest. I'm
very much a Linux newbie.. How do you start the daemon on the Linux
side? I've looked in the man pages, but no luck on actually starting it up.
TIA,
If you want to start a process on VM from linux, you only need the rexec
client program on Linux. The rexec daemon is started from inetd (or xinetd).
Look at /etc/inetd.conf (for inetd).
On Friday 28 March 2003 01:57 pm, you wrote:
Okay I've got the TCP/IP rexec daemon running on z/VM. Now
I don't think that the rexec daemon needs to be running on z/VM. To have
it start with a Linux SLES7 guest, modify the /etc/inetd.conf file:
execstream tcp nowait root/usr/sbin/tcpd in.rexecd
.thanks
Scott Archer wrote:
Okay I've got the TCP/IP rexec daemon running on z/VM.
forgive me if I keep hammering on this topic, but i'm still
not able to get this to work. I'm trying to get Linux guests
to respond to the CP SIGNAL SHUTDOWN command.
Using
SuSE SLES7 (2.4.7 kernel. This was downloaded from SuSE's
site as k-timer-2.4.7-20030221, dated Feb 21 2003.
Message-
From: Lucius, Leland [mailto:[EMAIL PROTECTED]
Sent: Friday, March 28, 2003 4:11 PM
To: [EMAIL PROTECTED]
Subject: Re: CP Signal shutdown requirements
-snip-
SLES8 does have the support built in since it was put into the kernel tree
somewhere between 2.4.17 and 2.4.19 (which SLES8
On a related note, you might consider using the rexec command from VM to
issue a '/sbin/shutdown -h now' to your Linux guests.
.thanks
Wolfe, Gordon W wrote:
We've just upgraded to z/VM 4.3 and would like to begin using the CP SIGNAL SHUTDOWN
command to shut down our Linux servers. We are
We've just upgraded to z/VM 4.3 and would like to begin using the CP SIGNAL SHUTDOWN
command to shut down our Linux servers. We are running SuSE SLES7 with the timer
patch,and I think I have the latest update.
When I try the SIGNAL command I get
HCPSIG2110E User LNX54321 is not enabled for
They later kernels from SuSE have the patch in it. My patch has been adapted
by the kernel folks so that it's different to the quiesce-diffs you've
located. SLES8 definitely has it. You'll need to update /etc/inittab to
enable the signal to do the ctrl-alt-del processing.
-Original