Re: [Elphel-support] Elphel NC353L-369 Master - Slave external triggering

2015-04-23 Thread Oleg
Jan,


 Just one last question - the frames do seem to be in sync now, but I
 wanted to ask whether it’s necessary to have the same TRIG_PERIOD set on
 both cameras in order for this to work or whether the TRIG_PERIOD doesn’t
 matter for the second camera as it just waits for the signal high?


You might have already tested it - yes, TRIG_PERIOD of the slave camera
does not have effect in this mode.

Best regards,
Oleg Dzhimiev
Electronics Engineer
phone: +1 801 783  x124
Elphel, Inc.
___
Support-list mailing list
Support-list@support.elphel.com
http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com


Re: [Elphel-support] Elphel NC353L-369 Master - Slave external triggering

2015-04-21 Thread Jan Blažíček
Ahh, so the middle two wires shouldn’t be crossed. No problem, thanks for the 
clarification. I am going to get right on it and report back.




Have a great day,

Jan Blazicek.

On Mon, Apr 20, 2015 at 10:30 PM, Oleg support-list@support.elphel.com
wrote:

 Apologies, there was a wrong wiring on the picture on our wiki - check out
 the corrected version
 http://wiki.elphel.com/index.php?title=File:Sync_cable.png.
 Best regards,
 Oleg Dzhimiev
 Electronics Engineer
 phone: +1 801 783  x124
 Elphel, Inc.___
Support-list mailing list
Support-list@support.elphel.com
http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com


Re: [Elphel-support] Elphel NC353L-369 Master - Slave external triggering

2015-04-21 Thread Jan Blažíček
Thank you very much Oleg, everything seems to be working, although it did 
require a bit of fiddling. I had a couple of times where the slave camera 
didn’t display any new frames, but didn’t stop responding either - things like 
the histogram in the web CCI would suggest the frames were actually getting 
processed.




That’s all sorted out now though, I’d post a solution for others, but it seemed 
to randomly fix itself when I reseted the parameters and repeated the 
triggering setup.




Just one last question - the frames do seem to be in sync now, but I wanted to 
ask whether it’s necessary to have the same TRIG_PERIOD set on both cameras in 
order for this to work or whether the TRIG_PERIOD doesn’t matter for the second 
camera as it just waits for the signal high? I just want to quickly make sure 
the second cam is really getting triggered and isn’t just getting a very 
similar signal from its own FPGA. I could always check the metadata though, so 
that’s not really much of a problem.




Thanks and good luck with your future projects,

Jan.___
Support-list mailing list
Support-list@support.elphel.com
http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com


Re: [Elphel-support] Elphel NC353L-369 Master - Slave external triggering

2015-04-20 Thread Oleg
Apologies, there was a wrong wiring on the picture on our wiki - check out
the corrected version
http://wiki.elphel.com/index.php?title=File:Sync_cable.png.

Best regards,
Oleg Dzhimiev
Electronics Engineer
phone: +1 801 783  x124
Elphel, Inc.
___
Support-list mailing list
Support-list@support.elphel.com
http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com


Re: [Elphel-support] Elphel NC353L-369 Master - Slave external triggering

2015-04-20 Thread Oleg
Hi Jan,


 In the second case TRIG is still 0, because as soon as I set that it stops
 responding.

That's what happens when you set up external triggering but the signals are
not received for some reason.

Another way to test your cable would be trying the following settings:
Master Camera:

 TRIG_PERIOD=3840
 TRIG_OUT=0x80 (send trigger signals to J15)
 TRIG_CONDITION=0x20 (trigger source - J15)
 TRIG=0x4


1. The order of applying TRIG and TRIG_CONDITION doesn't matter. If trigger
signal is not generated then the camera will stop responding after applying
the last parameter of these two.

2. If the Master camera doesn't stop responding then the cable and the port
are ok.

3. The Slave camera can have exactly the same settings - so, you can test
it in the Master mode as well - which only depends on the end of the sync
cable plugged in.

What results are you getting?

Best regards,
Oleg Dzhimiev
Electronics Engineer
phone: +1 801 783  x124
Elphel, Inc.
___
Support-list mailing list
Support-list@support.elphel.com
http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com