problem connecting to SMSC using SMPP 3.4

2009-11-19 Thread Stéphane Bruno
Hello all, I am trying to connect to an SMSC using SMPP 3.4. I am receiving the following error: [7] ERROR: connect failed 2009-11-19 11:30:28 [2889] [7] ERROR: System error 22: Invalid argument 2009-11-19 11:30:28 [2889] [7] ERROR: error connecting to server `IP_ADDRESS' at port `3717'

Re: problem connecting to SMSC using SMPP 3.4

2009-11-19 Thread Nikos Balkanas
...@vm1.kannel.org Sent: Thursday, November 19, 2009 6:33 PM Subject: problem connecting to SMSC using SMPP 3.4 Hello all, I am trying to connect to an SMSC using SMPP 3.4. I am receiving the following error: [7] ERROR: connect failed 2009-11-19 11:30:28 [2889] [7] ERROR: System error 22: Invalid

Re: problem connecting to SMSC using SMPP 3.4

2009-11-19 Thread Stéphane Bruno
to connect. Please give a real IP address and real credentials if you want to connect to your SMSc. BR, Nikos - Original Message - From: Stephane Bruno mysubscription...@gmail.com To: us...@vm1.kannel.org Sent: Thursday, November 19, 2009 6:33 PM Subject: problem connecting to SMSC

Re: problem connecting to SMSC using SMPP 3.4

2009-11-19 Thread Elton Hoxha
Maybe it has to do with system type parameter. You have it empty here, meanwhile it maybe configured at the smsc side. Ask from them what is system type name. On Thu, Nov 19, 2009 at 5:33 PM, Stéphane Bruno mysubscription...@gmail.com wrote: Hello all, I am trying to connect to an SMSC using

Re: problem connecting to SMSC using SMPP 3.4

2009-11-19 Thread Stéphane Bruno
They told me system-type should be empty... Stéphane On Thu, Nov 19, 2009 at 12:07 PM, Elton Hoxha elt...@gmail.com wrote: Maybe it has to do with system type parameter. You have it empty here, meanwhile it maybe configured at the smsc side. Ask from them what is system type name. On Thu,

Re: problem connecting to SMSC using SMPP 3.4

2009-11-19 Thread Alvaro Cornejo
Hi Try to telnet to port 3717 from your bearerbox machine. It might be a routing/firewall issue. Also ask provider their logs about your system trying to connect to their system. I 've seen providers that said they have done everything from their side and they haven't even create the account or

Re: problem connecting to SMSC using SMPP 3.4

2009-11-19 Thread Stéphane Bruno
Hello, I did all this. I did telnet on their IP and port, and the connection was successful. So, it is not a firewall/connectivity issue. The situation evolved now. I added the config parameter address-range to my config file, leaving it empty, and ti seems that the connection works now. Now, I