Hello all,
I am trying to connect to an SMSC using SMPP 3.4. I am receiving the
following error:
[7] ERROR: connect failed
2009-11-19 11:30:28 [2889] [7] ERROR: System error 22: Invalid argument
2009-11-19 11:30:28 [2889] [7] ERROR: error connecting to server
`IP_ADDRESS' at port `3717'
...@vm1.kannel.org
Sent: Thursday, November 19, 2009 6:33 PM
Subject: problem connecting to SMSC using SMPP 3.4
Hello all,
I am trying to connect to an SMSC using SMPP 3.4. I am receiving the
following error:
[7] ERROR: connect failed
2009-11-19 11:30:28 [2889] [7] ERROR: System error 22: Invalid
to connect. Please give a real IP address and real
credentials if you want to connect to your SMSc.
BR,
Nikos
- Original Message - From: Stephane Bruno
mysubscription...@gmail.com
To: us...@vm1.kannel.org
Sent: Thursday, November 19, 2009 6:33 PM
Subject: problem connecting to SMSC
Maybe it has to do with system type parameter. You have it empty here,
meanwhile it maybe configured at the smsc side. Ask from them what is system
type name.
On Thu, Nov 19, 2009 at 5:33 PM, Stéphane Bruno mysubscription...@gmail.com
wrote:
Hello all,
I am trying to connect to an SMSC using
They told me system-type should be empty...
Stéphane
On Thu, Nov 19, 2009 at 12:07 PM, Elton Hoxha elt...@gmail.com wrote:
Maybe it has to do with system type parameter. You have it empty here,
meanwhile it maybe configured at the smsc side. Ask from them what is system
type name.
On Thu,
Hi
Try to telnet to port 3717 from your bearerbox machine. It might be a
routing/firewall issue.
Also ask provider their logs about your system trying to connect to
their system. I 've seen providers that said they have done everything
from their side and they haven't even create the account or
Hello,
I did all this. I did telnet on their IP and port, and the connection
was successful. So, it is not a firewall/connectivity issue. The
situation evolved now. I added the config parameter address-range to
my config file, leaving it empty, and ti seems that the connection
works now.
Now, I