Have you run 'nodetool rebuild dc_india' on the new nodes? On Tue, Jan 24, 2017 at 7:51 AM, Benjamin Roth <benjamin.r...@jaumo.com> wrote:
> Have you also altered RF of system_distributed as stated in the tutorial? > > 2017-01-24 16:45 GMT+01:00 Abhishek Kumar Maheshwari <Abhishek.Maheshwari@ > timesinternet.in>: > >> My Mistake, >> >> >> >> Both clusters are up and running. >> >> >> >> Datacenter: DRPOCcluster >> >> ======================== >> >> Status=Up/Down >> >> |/ State=Normal/Leaving/Joining/Moving >> >> -- Address Load Tokens Owns Host >> ID Rack >> >> UN 172.29.XX.XX 1.65 GB 256 ? >> badf985b-37da-4735-b468-8d3a058d4b60 01 >> >> UN 172.29.XX.XX 1.64 GB 256 ? >> 317061b2-c19f-44ba-a776-bcd91c70bbdd 03 >> >> UN 172.29.XX.XX 1.64 GB 256 ? >> 9bf0d1dc-6826-4f3b-9c56-cec0c9ce3b6c 02 >> >> Datacenter: dc_india >> >> ==================== >> >> Status=Up/Down >> >> |/ State=Normal/Leaving/Joining/Moving >> >> -- Address Load Tokens Owns Host >> ID Rack >> >> UN 172.26.XX.XX 79.90 GB 256 ? >> 3e8133ed-98b5-418d-96b5-690a1450cd30 RACK1 >> >> UN 172.26.XX.XX 80.21 GB 256 ? >> 7d3f5b25-88f9-4be7-b0f5-746619153543 RACK2 >> >> >> >> *Thanks & Regards,* >> *Abhishek Kumar Maheshwari* >> *+91- 9999805591 <+91%2099998%2005591> (Mobile)* >> >> Times Internet Ltd. | A Times of India Group Company >> >> FC - 6, Sector 16A, Film City, Noida, U.P. 201301 | INDIA >> >> *P** Please do not print this email unless it is absolutely necessary. >> Spread environmental awareness.* >> >> >> >> *From:* Benjamin Roth [mailto:benjamin.r...@jaumo.com] >> *Sent:* Tuesday, January 24, 2017 9:11 PM >> *To:* user@cassandra.apache.org >> *Subject:* Re: [Multi DC] Old Data Not syncing from Existing cluster to >> new Cluster >> >> >> >> I am not an expert in bootstrapping new DCs but shouldn't the OLD nodes >> appear as UP to be used as a streaming source in rebuild? >> >> >> >> 2017-01-24 16:32 GMT+01:00 Abhishek Kumar Maheshwari < >> abhishek.maheshw...@timesinternet.in>: >> >> Yes, I take all steps. While I am inserting new data is replicating on >> both DC. But only old data is not replication in new cluster. >> >> >> >> *Thanks & Regards,* >> *Abhishek Kumar Maheshwari* >> *+91- 9999805591 <+91%2099998%2005591> (Mobile)* >> >> Times Internet Ltd. | A Times of India Group Company >> >> FC - 6, Sector 16A, Film City, Noida, U.P. 201301 | INDIA >> >> *P** Please do not print this email unless it is absolutely necessary. >> Spread environmental awareness.* >> >> >> >> *From:* Benjamin Roth [mailto:benjamin.r...@jaumo.com] >> *Sent:* Tuesday, January 24, 2017 8:55 PM >> *To:* user@cassandra.apache.org >> *Subject:* Re: [Multi DC] Old Data Not syncing from Existing cluster to >> new Cluster >> >> >> >> There is much more to it than just changing the RF in the keyspace! >> >> >> >> See here: https://docs.datastax.com/en/cassandra/3.0/cassandra/ >> operations/opsAddDCToCluster.html >> >> >> >> 2017-01-24 16:18 GMT+01:00 Abhishek Kumar Maheshwari < >> abhishek.maheshw...@timesinternet.in>: >> >> Hi All, >> >> >> >> I have Cassandra stack with 2 Dc >> >> >> >> Datacenter: DRPOCcluster >> >> ======================== >> >> Status=Up/Down >> >> |/ State=Normal/Leaving/Joining/Moving >> >> -- Address Load Tokens Owns Host >> ID Rack >> >> UN 172.29.xx.xxx 256 MB 256 ? >> b6b8cbb9-1fed-471f-aea9-6a657e7ac80a 01 >> >> UN 172.29.xx.xxx 240 MB 256 ? >> 604abbf5-8639-4104-8f60-fd6573fb2e17 03 >> >> UN 172.29. xx.xxx 240 MB 256 ? >> 32fa79ee-93c6-4e5b-a910-f27a1e9d66c1 02 >> >> Datacenter: dc_india >> >> ==================== >> >> Status=Up/Down >> >> |/ State=Normal/Leaving/Joining/Moving >> >> -- Address Load Tokens Owns Host >> ID Rack >> >> DN 172.26. .xx.xxx 78.97 GB 256 ? >> 3e8133ed-98b5-418d-96b5-690a1450cd30 RACK1 >> >> DN 172.26. .xx.xxx 79.18 GB 256 ? >> 7d3f5b25-88f9-4be7-b0f5-746619153543 RACK2 >> >> >> >> dc_india is old Dc which contains all data. >> >> I update keyspace as per below: >> >> >> >> alter KEYSPACE wls WITH replication = {'class': >> 'NetworkTopologyStrategy', 'DRPOCcluster': '2','dc_india':'2'} AND >> durable_writes = true; >> >> >> >> but old data is not updating in DRPOCcluster(which is new). Also, while >> running nodetool rebuild getting below exception: >> >> Cammand: ./nodetool rebuild -dc dc_india >> >> >> >> Exception : nodetool: Unable to find sufficient sources for streaming >> range (-8756974555527424852,-8755484427030035332] in keyspace >> system_distributed >> >> >> >> Cassandra version : 3.0.9 >> >> >> >> >> >> *Thanks & Regards,* >> *Abhishek Kumar Maheshwari* >> *+91- 9999805591 <+91%2099998%2005591> (Mobile)* >> >> Times Internet Ltd. | A Times of India Group Company >> >> FC - 6, Sector 16A, Film City, Noida, U.P. 201301 | INDIA >> >> *P** Please do not print this email unless it is absolutely necessary. >> Spread environmental awareness.* >> >> >> >> >> >> >> >> -- >> >> Benjamin Roth >> Prokurist >> >> Jaumo GmbH · www.jaumo.com >> Wehrstraße 46 · 73035 Göppingen · Germany >> Phone +49 7161 304880-6 <07161%203048806> · Fax +49 7161 304880-1 >> <07161%203048801> >> AG Ulm · HRB 731058 · Managing Director: Jens Kammerer >> >> >> >> >> >> -- >> >> Benjamin Roth >> Prokurist >> >> Jaumo GmbH · www.jaumo.com >> Wehrstraße 46 · 73035 Göppingen · Germany >> Phone +49 7161 304880-6 <07161%203048806> · Fax +49 7161 304880-1 >> <07161%203048801> >> AG Ulm · HRB 731058 · Managing Director: Jens Kammerer >> > > > > -- > Benjamin Roth > Prokurist > > Jaumo GmbH · www.jaumo.com > Wehrstraße 46 · 73035 Göppingen · Germany > Phone +49 7161 304880-6 <+49%207161%203048806> · Fax +49 7161 304880-1 > <+49%207161%203048801> > AG Ulm · HRB 731058 · Managing Director: Jens Kammerer > -- Dikang