No, the KCC and ISTG have not been disabled. 
Some EA in my forest created many manual connection objects between sites AND 
within a site.

I apologize for leaving the previous thread, but I felt that thread was dead 
until I could get some more info and I thought I'd create a new one just to see 
if I can get the question of wheter its a bad idea to create manual connection 
objects(either between sites or within a site) answered.
Also, I'm not sure this relates to my other issue either. its a chicken and egg 
thing, I guess.
Anyway, my apologies
thanks



Dean Wells wrote:
> Does this question relate to your previous thread(s)?  If so, can you
> keep the questions within the thread?
> 
> Are you implying that the KCC or ISTG or both have been disabled?  If
> the KCC has been disabled, that would explain your earlier error.
> 
> In general, it is acceptable to disable the ISTG and create manual
> connection objects between sites if you've a good reason to do so, it
> is not recommended to use manual connection within a site as it is
> (in nearly all cases) unnecessary.  Numerous public documents exist
> that describe Microsoft's scenario-specific recommendations on this
> topic.  Since it is a scenario-specific topic, I'd recommend that you
> also take a look at those. 