Thanks, that's an interesting one. ________________________________ From: AF <[email protected]> on behalf of Joe Novak <[email protected]> Sent: Monday, August 3, 2026 1:47 PM To: AnimalFarm Microwave Users Group <[email protected]> Subject: Re: [AFMUG] 48VDC Rectifier for small enclosure - remote OLT
I'm getting ready to deploy this setup: https://ict-power.com/product/din-series-power-supply/ https://ict-power.com/product/ict-din-pdu6/ Had it on the bench today, I'm happy with it. Don't forget to order fuses for the PDU like we did :) Jury is still out on how it works in the field, but I think it should be fine. Thanks, Joe On Mon, Aug 3, 2026 at 12:21 PM Ken Hohhof <[email protected]<mailto:[email protected]>> wrote: Still using Traco TSP-BCM48 and “Battery OK” contact to SiteMonitor. I would not particularly recommend the BCMU except for special cases. I have one DC site with an Eltek Micropack which has web management as well as N+1 rectifier redundancy, it’s been fine but it’s overkill. From: AF <[email protected]<mailto:[email protected]>> On Behalf Of Adam Moffett Sent: Monday, August 3, 2026 11:58 AM To: 'AnimalFarm Microwave Users Group' <[email protected]<mailto:[email protected]>> Subject: Re: [AFMUG] 48VDC Rectifier for small enclosure - remote OLT All of the above. AC to 48VDC + battery backup. I never had an issue with Traco or Meanwell for this either, but it's been some years since I've done it so I wondered if there was some hot new product people liked. To read the dry contacts on your Traco/Meanwell stuff do we still like Packetflux? It'd be nice if there was a Sitemonitor with a gigE port. ________________________________ From: AF <[email protected]<mailto:[email protected]>> on behalf of Ken Hohhof <[email protected]<mailto:[email protected]>> Sent: Monday, August 3, 2026 12:13 PM To: 'AnimalFarm Microwave Users Group' <[email protected]<mailto:[email protected]>> Subject: Re: [AFMUG] 48VDC Rectifier for small enclosure - remote OLT Are you looking for just an AC/DC power supply, or a battery management system? When you say rectifier, that conjures up mental images of something charging telco CO batteries. Oh, and I echo what Chuck said, I don’t think I’ve ever had a Traco or Mean Well device fail. I’ve used some Phoenix Contact in the past, no reason to pay the premium price for German stuff. From: AF <[email protected]<mailto:[email protected]>> On Behalf Of [email protected]<mailto:[email protected]> Sent: Monday, August 3, 2026 10:49 AM To: AnimalFarm Microwave Users Group <[email protected]<mailto:[email protected]>> Subject: Re: [AFMUG] 48VDC Rectifier for small enclosure - remote OLT I have used both. Never a problem. I think Calex uses one or the other of them to do their MDU ont box. ________________________________ From: AF <[email protected]<mailto:[email protected]>> on behalf of Adam Moffett <[email protected]<mailto:[email protected]>> Sent: Monday, August 3, 2026 9:43 AM To: 'AnimalFarm Microwave Users Group' <[email protected]<mailto:[email protected]>> Subject: [AFMUG] 48VDC Rectifier for small enclosure - remote OLT I've used Traco and Meanwell DIN rail rectifiers for wireless before. Since it's been a few years, I wonder how the market has changed. I see the Traco TSP-600 is still around, and I had no real complaints with that one. I was thinking about those types of systems for powering 8-port remote OLT's. Are there models you guys use or recommend? -Adam -- AF mailing list [email protected]<mailto:[email protected]> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
-- AF mailing list [email protected] http://af.afmug.com/mailman/listinfo/af_af.afmug.com