You've already checked for grounding issues and nearby 2-way transmitters around 100-150mhz?
On Tue, Apr 21, 2015 at 2:05 PM, Eric Muehleisen <[email protected]> wrote: > A while back there was a thread about issues running CAT5 cables along the > entire length of solid steel tower legs. > > We've run into a problem where we can't run 100baseT reliably on a couple > APs. CRC errors will go away if we force the switch port to 10baseT. > Interestingly enough, packet loss amplifies when it rains. > > Any help would be appreciated. > > > -- > Sent via mobile >