Ours manifested itself as just enough inductance to trigger our surge 
suppressors. With a fast enough ping, you could see the 1pps in the packet loss.

 

 

 

From: Af [mailto:[email protected]] On Behalf Of Eric Muehleisen
Sent: Tuesday, April 21, 2015 2:31 PM
To: [email protected]
Subject: Re: [AFMUG] CAT5 crosstalk on tower legs

 

That's it! It's coming back to me now. This is affecting only Canopy APs with 
sync over power going into a CTM2. 

 

What would be the best wiring or pin out method in this case?

On Tuesday, April 21, 2015, Chuck McCown <[email protected] 
<mailto:[email protected]> > wrote:

LMG discovered this about 10 years ago or whenever their first sync product 
came out.  The fix was the balanced sync over power wiring schema.

 

From: Ken Hohhof <javascript:_e(%7B%7D,'cvml','[email protected]');>  

Sent: Tuesday, April 21, 2015 1:24 PM

To: [email protected] <javascript:_e(%7B%7D,'cvml','[email protected]');>  

Subject: Re: [AFMUG] CAT5 crosstalk on tower legs

 

The thread about Cat5 ziptied to tower legs probably involved sync over power 
and surge protectors.

 

From: Josh Luthman 
<javascript:_e(%7B%7D,'cvml','[email protected]');>  

Sent: Tuesday, April 21, 2015 2:12 PM

To: [email protected] <javascript:_e(%7B%7D,'cvml','[email protected]');>  

Subject: Re: [AFMUG] CAT5 crosstalk on tower legs

 

Damn near every tall tower I've done straight up the legs and zip tied right 
onto the legs. 

 

Grab shielded cabling and do it again, I bet you have water in the line.  
Double check your connectors at the bottom for corrosion or water.

 

 

Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373

 

On Tue, Apr 21, 2015 at 3:05 PM, Eric Muehleisen <[email protected] 
<javascript:_e(%7B%7D,'cvml','[email protected]');> > wrote:

A while back there was a thread about issues running CAT5 cables along the 
entire length of solid steel tower legs.  

 

We've run into a problem where we can't run 100baseT reliably on a couple APs. 
CRC errors will go away if we force the switch port to 10baseT. Interestingly 
enough, packet loss amplifies when it rains.

 

Any help would be appreciated. 



-- 
Sent via mobile

 



-- 
Sent via mobile

Reply via email to