At the site where I get water down the cables (it doesn’t take much to cause problems), it comes from a Powerbridge and a Syncpipe, so far no water from the 450 APs. So I’m thinking the cable itself may not be the source of the leak. The Syncpipe is cheaper cable, but the Powerbridge has the same Belden shielded cable as the 450 APs. Can’t wait to replace all Powerbridges, maybe with AF5X and the 23 dBi dish.
From: Mike Hammett Sent: Sunday, May 10, 2015 9:25 AM To: [email protected] Subject: Re: [AFMUG] APC-DIN Mount Yeah, I've done that after the fact to drain a cable, but I have a hard time purposely cutting the jacket of a cable outside when it hasn't done anything wrong yet. (Yes, I blame the cables for being wrong.) ----- Mike Hammett Intelligent Computing Solutions http://www.ics-il.com Midwest Internet Exchange http://www.midwest-ix.com -------------------------------------------------------------------------------- From: "Chuck McCown" <[email protected]> To: [email protected] Sent: Sunday, May 10, 2015 9:22:44 AM Subject: Re: [AFMUG] APC-DIN Mount Maybe strip back the cable a bunch so the water has a chance to escape. Or make a ring cut on the jacket where the cable is at a low point. From: Mike Hammett Sent: Sunday, May 10, 2015 8:20 AM To: [email protected] Subject: Re: [AFMUG] APC-DIN Mount A drip loop doesn't help when the water is on the inside. You've got however high up it is to the nick in the cable's worth of head pressure. Could have been poor installation, could be birds, squirrels, etc. If you get water in, it'll come out the end. I've met up to three squirrels on the way up the grain leg. That's always a pleasant feeling when you're ascending and you find a little brown fluffy critter.... and then another... and then another. ----- Mike Hammett Intelligent Computing Solutions http://www.ics-il.com Midwest Internet Exchange http://www.midwest-ix.com -------------------------------------------------------------------------------- From: "Chuck McCown" <[email protected]> To: [email protected] Sent: Sunday, May 10, 2015 9:14:54 AM Subject: Re: [AFMUG] APC-DIN Mount We just buy APC PRM4s and put a nice metal din rail mount on the back. It is screwed on. You could un screw it and mount it elsewhere. I presume you have good drip loops that keep water from following the cables to the surge suppressors. From: Mike Hammett Sent: Sunday, May 10, 2015 7:45 AM To: Animal Farm Subject: [AFMUG] APC-DIN Mount It's hard to tell from the picture. Must the chassis be mounted to the DIN rail via the back of the chassis or can the mount be relocated to the top\bottom? I assume it can't be moved, but I'd like to mount it so that the ports of the surge suppressors are pointing down. Should any water enter the cable, gravity would take it back out of the connector, down the side of the cable instead out the back of the connector, down onto the next surge suppressor below it. I could just put a DIN rail at the top of the box, but just wondering if I could just use the same rail I'm using for everything else. No, it's not green cable and there shouldn't be any wear points, so I'm not really sure how it's getting in. ----- Mike Hammett Intelligent Computing Solutions http://www.ics-il.com Midwest Internet Exchange http://www.midwest-ix.com