We have a site with two PMP450 APs, and one PTP450.
We installed the two PMP450s first, and then several months later added
the PTP450.
The PMP450s are synced via a basic sync pipe through a sync injector.
Because the PTP450 only takes sync over timing, we added a second
parasitic sync pipe.
Is there a simple way to provide sync to all three with one sync pipe?
And I don't want to split timing cables. I would "like" to keep running
the sync injector because it's just plain cleaner, and less prone to
issues. But I need to get timing to the PTP450 too.
Is there a way to tap the sync pulse from the sync injector, and run it
into the PTP450?
--
bp
<part15sbs{at}gmail{dot}com>