Can you enable Sync Output to RJ-11 port on one of the APs and run an RJ11 cable between it and the PTP450 to the timing port?
On Fri, Jul 31, 2015 at 5:06 PM, Bill Prince <[email protected]> wrote: > We have a site with two PMP450 APs, and one PTP450. > > We installed the two PMP450s first, and then several months later added > the PTP450. > > The PMP450s are synced via a basic sync pipe through a sync injector. > Because the PTP450 only takes sync over timing, we added a second parasitic > sync pipe. > > Is there a simple way to provide sync to all three with one sync pipe? And > I don't want to split timing cables. I would "like" to keep running the > sync injector because it's just plain cleaner, and less prone to issues. > But I need to get timing to the PTP450 too. > > Is there a way to tap the sync pulse from the sync injector, and run it > into the PTP450? > > -- > > bp > <part15sbs{at}gmail{dot}com> > >